打印
M204F Passive Infrared

Power supply voltage:AC/DC12-30(-0//+15//)          Power consumption: about 15mA  Temperature range:-40º C-60º C         Maximum install degrees:3.5m      Maximum detection area:3*1.5m    Output hold time:0.1m/s       Tilting angle: 0 to 6 º C      Hole size: 70 (length) * 23 (W) * 49 (H) mm

Details

induction supporting for a variety of automatic doors , particularly suitable for automatic revolving door induction starter or to automatic sliding doors, which can be built-in installation, can also be installed External.
Power supply voltage:AC/DC12-30(-0//+15//)          Power consumption: about 15mA  Temperature range:-40º C-60º C         Maximum install degrees:3.5m      Maximum detection area:3*1.5m    Output hold time:0.1m/s       Tilting angle: 0 to 6 º C      Hole size: 70 (length) * 23 (W) * 49 (H) mm
By adjusting the focus point, the detector can easily detect the specified focus area. AWG signal contacts output, normally open normally closed adjustable so that the sensor cable is disconnected or a power outage in the case, can send positive detection. Using a full passive detector parts imported from Germany, reasonable structure design, anti-interference, high sensitivity, the unique design of controlled optical zoom devices.  

 

 

Safety Tips
This device must use the safety belt to protect low-voltage insulation¡£
All regulation and repair work must be done by professional engineers  to carry out the installation¡£

 

 

Technical indicators and parameters
Operating voltage : AC/DC 12¡×30(-0%+15%)
Power consumption : approximately  15mA
Temperature range : -40¡æ-60¡æ
Temperature range: 3.5m
Maximum installation height: 3¡Á1.5m
Maximum field size: 0.1m/s
Output hold time: 0.5s
Protection class: IP 52
Relay contact load: -maximum switching current 1A
-maximum contact voltage: 48VAC/48VDC
-maximum switching capacity: 30W/60VA
Overall Dimension: 100mm(L)  Á 35mm(W)¡Á 37mm(H)            
 
[for more technic parameter,pls check download area]